+-------------------------------------------------------------------------------+ | This file include all information's about Changes in the different Versions. | | | | xxxx represent the PC-DMIS supported PC-DMIS Main Version | | y represent the PC-DMIS supported MR Number of the Main Version | +-------------------------------------------------------------------------------+ Version 5.xxxx.y39 - Fixed a issue where several catalog files were not found. - New function "ProtectedMode" allows to lock the settings by the administrator. Version 5.xxxx.y38 - Output K2991 (PC-DMIS ID) can be deactivated. Version 5.xxxx.y37 - Output sequence in the DFX file changed at Ford's request (K-fields with /0 are printed first). Version 5,xxxx,y36 - Fixed an issue (Run-time error '13': Type mismatch), if the last axis of a legacy TruePosition dimension was not the TP axis. - Solving a problem (run-time error '91') when elements in subroutines    were measured, the review of the "Skipped Flags" failed. The element    was not found in PcdCmds and thus the subject variable was not set.    Currently, the converter assumes that the elements in subroutines are not    skipped (un-marked is detected). Version 5.xxxx.y35 - Protect the software against closing during Online mode (CASE 00114584) Version 5.xxxx.y34 - Fixed an issue with distance dimensions in Online mode (CASE 112236) Version 5.xxxx.y33 - Fixed an issue with the language file after Update - Optimized support for GAGE/Temperature Command - Correct Unit (C) - Corect lower tolerance value - Output is now limited to the axis (before also the header line was reported as a charcteristic). Version 5.xxxx.y32 - INI file value Webasto NameRule corrected. Depending on the language of the operating system a runtime error could occur with the old setting. Version 5.xxxx.y31 - New default value for K8500 (sample size (total)) is now 2 (previously 5) - New default value for K8501 (sample type) is now 1 (sliding --- before none) - When creating a new PCDQDAS.INI file, the following entries are also written: - "AdvancedSettings" - "DefaultValueK2005", "3"     - "AdvancedSettings" - "WebastoNameRule", "Wrong"     - "AdvancedSettings" - "chkUseDefaultValueK2005", "1" - Solution for K2001 value in conjunction with position features and V1 compatible axis identifiers - K2991 Value for different feature types extended by the AxisLetter and Feature1 ID removed This K-field is used to update data in the PC-DMIS Q-DAS Configurator using a DFQ file created by the converter. - New integration for attributive features (good - bad as single storage (K8503 = 2))   - Tracefield named ATTRIBUT with the value 0 (good) and 1 (error) generates this feature   - It is recommended to use a Tracefield K2001 with the ID of the feature in advance - New support of position evaluations with LMC / MMC condition and resulting bonus tolerance - 3 variants are supported (setting in the setup dialog): - As in the previous versions (position is sent only with the basic tolerance) - An additional attribute (good / bad) is added to the group - An additional normalized feature is added to the group Upper tolerance + bonus equals 1 Measured Value = Deviation / (Upper tolerance + Bonus)) - New Support for K2091 Characteristic index [20] A as Tracefield command TRACEFIELD/DISPLAY=NO,REPORT=NO,DISPLAY MESSAGE=K2091 ; K2091 : X=MyXValue| Y=MyYValue | Z=MyZValue - New Support for K2092 Characteristic text [50] A as Tracefield command TRACEFIELD/DISPLAY=NO,REPORT=NO,DISPLAY MESSAGE=K2091 ; K2091 : X=MyXValueLong| Y=MyYValueLong Version 5.xxxx.y30 - Adjustments for ftp Upload - New Automation checkbox in Setup. This will force the converter to a silent end if no output data are available. Version 5.xxxx.y29 - Added support for lower acceptance limit (K2116 and K2117). The value will be defined in a tracefield using the name K2116_K2117. The value is defined in percent (e.g. value 70 = 70% of the tolerance). TRACEFIELD/DISPLAY=NO,DISPLAY MESSAGE=K2116_K2117 ; K2116_K2117 : 70 The tracefiled can be repeated in the measuring routine if the value will be changed for different dimension commands. - Fix for K2991 - for legacy form dimensions the axis letter was missing - K2005: New Q-DAS Flags HI=5 and OS=6 was added for Ford rules. - K0004, K0006, K0007, K0008, K0010, K0012 and K0053 will be only written ones using /0 if Ford rules are active. - Independend of the character in the Feat1 ID X,Y and Z will be written in the Q-DAS ASCII files (valid only for Ford naming rules). - Change of QDAS E Tracefield handling to timer function to protect against Server busy error message - Check if PCDLRN process exist before GetObject. - Fix in ftp upload protocol Version 5.xxxx.y28 - Bugfix for K2002. Using specific seetings the axis letter was used 2 times. Version 5.xxxx.y27 - Bugfix for output of K0061 Version 5.xxxx.y26 - K1209 is supported now also as a tracefield command Version 5.xxxx.y25 - Bugfix in Online mode. Before a Runtime error 91 was shown during the converter get the data from FCF commands. Version 5.xxxx.y24 - Output CAD centroid of Feat1 - Output CAD Vector of Feat1 This happens only if the file C:\ProgramData\PCDQDAS\Settings\K-Fields_for_CAD_Data.dat exists. In this file the user can define which K-fields will be used for the output. Example of the file content: X:K2091 Y:K2092 Z:K2093 I:K2095 J:K2096 K:K2097 - Added K2991 support for PcdId. This K-field is not used by Q-DAS. It was reserved especially to synchronize data from the converter with the new PC-DMIS Q-DAS configurator. Version 5.xxxx.y23 - Changed format check for K0008. The new version will allow now up to 10 digits. Version 5.xxxx.y22 - A Predefined Q-DAS Folder can contain now also a full path. The old mode is still supported. In the past it was always a subfolder of C:\ProgramData: C:\ProgramData\PCDQDAS\Settings\QdasStandardProductionDirectory.dat: \Q-DAS\V_11\CommonFiles\HexagonMetrology C:\ProgramData\PCDQDAS\Settings\QdasMSADirectory.dat: \Q-DAS\V_11\CommonFiles\Data\Examples\ENG\GC\_Own_MSA_Study Now you can use also e.g.: C:\Temp C:\Temp\MSA Version 5.xxxx.y21 - Updated operater manual - Correction of the directories for files, in which the settings were saved.    These are now stored in C:\ProgramData\PCDQDAS\Settings. Version 5.xxxx.y20 - Added Support for Lower and Upper Scrap Limit (K2114 und K2115). The dimension related values can be set using tracefield commands in PC-DMIS. Here you can see an example which represents the write mode of the values: TRACEFIELD/NO_DISPLAY,LIMIT=255 ; K2114 : LOC1.X:-0.7|LOC1.Y:-0.3|LOC1.D:-0.5 TRACEFIELD/NO_DISPLAY,LIMIT=255 ; K2115 : LOC1.X: 0.7|LOC1.Y: 0.6|LOC1.D: 0.4 The position of the tracefield in the measuring routine is unrelated to the position of the dimension. Reason is the special selected write mode which is using the dimension id and the axis letter to identify the correct dimension for the values. Important is also that the correct seperators '|' and ':' are used because they are defining the split positions inside the string. - A problem has been solved if the value for K2002 is to be taken from a comment text in the measurement routine and there is no comment in the measurement routine. This resulted in the fact that no features were output in the Q-DAS file. The correct value is that the value in the K2002 field indicates that there is no comment in the measurement routine. - A problem during the language selection of Hungarian and Slovenian was solved. - A problem during the initial catalog selection was solved. Version 5.xxxx.y19 - In advanced settings can now be decided whether for K2005 a default value is to be output. If so, a value can be 0, 1, 2, 3, or 4 can be set. The default values were chosen to ensure compatibility to the previous version. Since version 4.xxxx.y27 always a 1 is used, unless a different default value was defined in the measurement routine (Tracefield K2005/0). Version 5.xxxx.y18 - Files for 4 digit file counter will be saved now in C:\ProgramData\PCDQDAS\PartData Before they was created in a subfolder PartData inside of the installation folder. To protect any missmatch it will be required to copy the content of the old folder in the new folder. - Changed K2001 Value for V1 compatible axis letter Version 5.xxxx.y17 - Added support for Tracefield K0080 and K0081 - Based on input from Q-DAS the automatic "#" character was removed from K0006 - Added support for K1071 [20] A (Supplier Number Text) Version 5.xxxx.y16 - Part GUID moved from K1002 to K1997 (request from Smart Quality / Q-DAS) Version 5.xxxx.y15 - Added support for Tracefield K1043 A [40] Version 5.xxxx.y14 - Added CeCreator Version 1.0.4.0 - Switched File extension .cfg to .ce_cfg (reason was a conflict with PC-DMIS OI) Compatibility with previous cfg files csn be solved by manual renaming of the files. - K1083 data check fix up to 99.999 instead of 32.767 (data type changed from integer to long + limit 99.999) Version 5.xxxx.y13 - Added CeCreator Version 1.0.3.0 - Fix for empty characters in Dimension and Feature IDs Version 5.xxxx.y12 - CeCreator can be used also for K-Field notation in Q-DAS ASCII file - Added CeCreator Version 1.0.2.0 - Fix for replacement of the values (before it was possible that the numbers inside of K-Field was changed (e.g. K2001/1 1 ==> K200A/A A) - Speed improvement Version 5.xxxx.y11 - Support for the new CeCreator argument /ICS - CeCreator 1.0.1.0 - The CeCreator can be useed now also in silent mode (argument /ICS) - The Key-Field which should be replaced can be selected now (usually K2001 or K2002). For this setting there is a file in the installation folder of the CeCreator (KFeldSetting.dat). In the first row of the file ther must be the Key-Field (e.g. K2001) Version 5.xxxx.y10 - Slovenian language support - Set default Value for K1009 (BODY) in in combination with Ford rules - Added support for CeCreator (Start arguments (OC, AC or IC) CeCreator is an add on software which allows to set individual values for K2001. Starting with this version the software will be installed automatically with the Q-DAS Converter. Version 5.xxxx.y09 - Added support for K1110 [20] A (Order number) - Added support for K1111 [20] A (Goods received number) - Added support for K1311 [40] A (Production order) - Added support for K1341 [20] A (Test plan number text) Version 5.xxxx.y08 - Fixed an issue with lower natural boundary for the following dimension types: DIMENSION_CIRCULAR_RUNOUT DIMENSION_CIRCULARITY DIMENSION_CYLINDRICITY DIMENSION_TOTAL_RUNOUT Version 5.xxxx.y07 - GetObject was assigned to a specific PC-DMIS Version(2015.1). By this reason the converter version y06 was only usable with PC-DMIS 2015.1. Version 5.xxxx.y06 - Added grouping support for 1D and 3D true position dimensions. - K8500 Default Value is now 5. The K-field will always printed in the Q-DAS ASCII file. - Removed the # from K0006 - Fix for QDAS_FLAG Tracefield (Support for empty character before and after the seperator): old: X=SC;CTQ;BC|Y=CTQ;BC|Z=BC new: X=SC;CTQ;BC | Y=CTQ;BC | Z=BC Version 5.xxxx.y05 - Added additional Debug informations. - Added msflexgrd.ocx to installer Version 5.xxxx.y04 - Added support for K1221 [20] A (Prüfername Text) as trace field value - Added support for new Tracefield write mode for K2005, K2006, K2007 and K2434. Example: TRACEFIELD/NO_DISPLAY,LIMIT=255 ; QDAS_FLAG R912BCA0A846 : X=SC;CTQ;BC|Y=CTQ;BC|Z=BC SC is in this example a user defined value for K2005 CTQ is in this example a user defined value for K2006 BC is in this example a user defined value for K2434 For the setup of this values a new Setup for Tracefield values was added. Version 5.xxxx.y03 - If the execution of the measuring routine will be canceld, the converter can stay open in an active status. The measuring routine can be continued (e.g. using + an the data collection continues. The previous collected data won't be lost. It's in the operators responsibility that no characteristics will be executed multiple times. Version 5.xxxx.y02 - Added Support for PartGuid (MMS) for K1001 Version 5.xxxx.y01 - First free of charge version for our Q-DAS customers. - Support for predefined output folders for Q-DAS O-QUIS and Solara - Support for Trace field with the name 'FirstPart' to identify a reworked part (second measurement of the same part). Possible values are 0 (reworked) or 1 (new). This information is needed if the result depending subfolders will be used. - If the trace field K1203 the value will be 'MSA', the target folder will be automatically changed to the Solara folder and line write and append mode will be enabled. Please make sure that the file name is not using a 4digit counter or date/time stamp. - Adjusted order of Tab stops in the setup dialogue for k-fields - Added the k-field numbers ([K2001] and [K2002]) in the advanced setting dialog - Problem with language settings after a new installation fixed. - Settings, Languages, Catalogs, PartData and TempData folder moved to the Windows %ProgramData%\PCDQDAS\ folder - Debug files will be saved now in %ProgramData%\PCDQDAS\ - ftp Upload dialogue will be automatically closed after 5 seconds after the Batch file was started. ------------------------------------------------------------------------------------- Version 4.xxxx.y49 - Added support for K1003 (Part Short Description) as Tracefield value. Output is only done if a value is defined in the measuring routine. - Changed K0010 and K0012 from Type Integer to Long. By this change now 10 digits can be supported. Version 4.xxxx.y48 - Added Support for K2015/0 and K2015. Value 0,1 or 2 will be send by tracefield using name K2015 for one individual dimension axis. If a dimension is using more then one axis the values will be separated in one tracefiled with ','. Example: 1,0,2 A default value can be set by a tracefield using name K2015/0. The value will be used for each axis which is not defined individually. Version 4.xxxx.y47 - K2009 Value for characteristic type FCF Flatness changed (from 102 to 101) - Additional rule for K2002 (Characteristic name) added in the advanced settings. This rule is using only the Feature 1 ID and tthe axis letter. No other feature or dimension IS's will be used. - Format check for K0008 changed from Typ Integer to Long. Version 4.xxxx.y46 - Problem with dual arm machines and Protocol Comments for K2002 fixed Version 4.xxxx.y45 - Added support for K2093/0. Value will be send by tracefield using name K2093/0. - Added support for K2095/0. Value will be send by tracefield using name K2095/0. - Added support for K2096/0. Value will be send by tracefield using name K2096/0. - Added support for K2097/0. Value will be send by tracefield using name K2097/0. - Added support for K2311/0. Value will be send by tracefield using name K2311/0. Version 4.xxxx.y44 - Added tracefield support for K0005/0 (correct syntax is under the responsibility of the PC-DMIS part program value) - Added tracefield support for K0062 to K0063 - Added tracefield support for K0054 to K0060 Version 4.xxxx.y43 - Fix for Online reading of K0061 trace value Version 4.xxxx.y42 - Added support for K0061 Version 4.xxxx.y41 - Bugfix for Monitoring path. The '\' between the selcted folder and the subfolder for the part was missing. Version 4.xxxx.y40 - Added support for control type (Tracefield K2007 and K2007/0). For dimensions with multiple rows the values can be separated with a comma. 0 no Control 1 conditional Control 2 manual 3 automatic Control Version 4.xxxx.y39 - Problem fix while reading K2001 and K2003 from a tracefield for the first characteristics in the part program Version 4.xxxx.y38 - Ford naming rule "V" uses also RT (before only T) Version 4.xxxx.y37 - With negative Y coordinates and positive reporting the values of the upper and lower plausibility limits were twisted. Version 4.xxxx.y36 - K0002 Attribute was showing 0 as the value if a dimension was not marked, but the related feature was measured. Version 4.xxxx.y35 - New argument /O which can be used if the converter should bee started at the end of the part program. The dimensions will be reasd automatically, but the Q-DAS Output have to be started from the user. Version 4.xxxx.y34 - Bug fix in Path name for the Audi PBMS Converter - Audi PBMS Converter Checkbox in Setup Version 4.xxxx.y33 - Integration of AUDI PMBS Converter, if DFQ file and Using Line Notation is selected. AUDI PMBS Converter must be installed din the same folder as PC-DMIS - Q-DAS Converter (subfolder "PC-DMIS Audi PBMS Konverter") Version 4.xxxx.y32 - Bug fix for getting the tracefieldvalues for K0006 in combination with Ford naming rules (up to 20 characters) Version 4.xxxx.y31 - Bug fix for getting the tracefieldvalues for K2003 in Online mode. Version 4.xxxx.y30 - K2003 is now supported as a tracefield command. The position of the tracefield must be before the next dimension command. If the dimension has more than one axis the values can be separated by a comma. Each single value has maximum 20 characters. Version 4.xxxx.y29 - With selected Ford naming rules the K-Field K0006 can now use up to 20 characters (before25). Version 4.xxxx.y28 - Additional fix for K2005. - Fix for calculation of plausibility limits in combination with positive reporting. - With selected Ford naming rules the K-Field K0006 can now use up to 25 characters (this is not Q-DAS ASCII conform) Version 4.xxxx.y27 - K2005 characteristic class was defaulted since 4.2.1 of the converter to a value of 1, if no trace field K2005 in the measuring program for the characteristic has been defined. As a result, the globally defined value from the data entry screen of the converter or the trace field K2005/0 but has been overridden. Now, the value for the single characteristic is used only on 1, if no individual and no global value has been defined. Known bug: - With the use of positive reporting in PC DMIS the plausibility limit is incorrectly calculate at negative Y-axis nominal values. Also the positive reporting will be only used only for Y axis values. Basically the command for the positive reporting in PC-DMIS must be evaluated in more detail by the converter (which axis?; what values?) Version 4.xxxx.y26 - Implemeted check for length of K0006 value in data input form. If the value is longer as 14 charcters, the software will cut the string to 13 charaters and a '#' will be insert as Prefix. Version 4.xxxx.y25 - Bug Fix for calculation of plausibility limits Version 4.xxxx.y24 - With multiplier 0 the output of plausibilty limits can be inhibited (K2130 und K2131) Known issue: - If the lower toleranz is higher as the nominal value (positive) the calculation of the plausibility limits is wrong. Version 4.xxxx.y23 - Bug Fix for calculation of lower plausibility limit (K230) if the dimension is using a natural boundary Fehlerbehebung für Plausibilitätsgrenzenberechnung bei natürlich begrenzten Merkmalen. Version 4.xxxx.y22 - Bug fix for switch Language. - If the output format is not writing lines and already exists a file with same name, a message will be displayed. Version 4.xxxx.y21 - Bug fix for output of K2900 Version 4.xxxx.y20 - For distance dimensions (pitch points) the converter uses now the dimension ID instead of the feature 1 ID (if Ford rules are selected). Version 4.xxxx.y19 - Added Support for K2003 which will include the Feat1 ID (required for Ford CM4D) Version 4.xxxx.y18 - Fix for Run-time error '380': Invalid property value Max Value of progress bar was smaller as number of PC-DMIS events. Reason is that PC-DMIS starting from Version 2011 sends more events as number of commands are included in the part program Version 4.xxxx.y17 - Removed the check for Administrator privilegs in the setup dialogs. Version 4.xxxx.y16 - The line notation has been corrected. Version 4.xxxx.y15 - Fixed background color in the amin view if the value is less then 0. Version 4.xxxx.y14 - ftp Upload form always on top Version 4.xxxx.y13 - Support for K1900 as Tracefield (befor only available in the interface) - Support for attributive Prüfung (K2004/xx 1) integrated. PC-DMIS Examplecode for such a characteristic: ASSIGN/YES_STRING=GETSETTING("LangStr(YES)") TRACEFIELD/NO_DISPLAY,LIMIT=15 ; K2001 : AMM1 C1 =COMMENT/YESNO,NO,FULL SCREEN=NO,AUTO-CONTINUE=NO, Please check the charasteristic manually. Is the part OK? Part OK: Please press Part not OK: Please press IF/C1.INPUT==YES_STRING ASSIGN/ATCHECK=1 END_IF/ ELSE/ ASSIGN/ATCHECK=0 END_ELSE/ TRACEFIELD/NO_DISPLAY,LIMIT=1 ; K2004 : ATCHECK Version 4.xxxx.y12 - Fix in combination with K2009 and Feature Control Frames Version 4.xxxx.y11 - Support for K1083, K1201 as Tracefield command - Support for K2009 (will be automatically detected by the dimension type) Version 4.xxxx.y10 - Flip for axis X and Z removed if K2203 is set to 1 (Karosseriemodus) Version 4.xxxx.y09 - Changed handling of the form if the answer is NO after the part program was cancled. Version 4.xxxx.y08 - If a part program execution was canceled, the Q-DAS converter will automatically pop up in the foreground. Version 4.xxxx.y07 - Before the Q-DAS ASCII file will be generated the execution status of the features in the dimension commands will be checked (SKIPPED Property). If the feature was skipped or unmarked the attribute will be set to 255 or 256. Also the features in attached part programs will be checked. Version 4.xxxx.y06 - Code change for the new Registry structure of PC-DMIS (DecimalPrecissionDefaultValue) Version 4.2010.5 / 4.2009.5 - Software version linked for PC-DMIS 2009 and 2010 . Version 4.2010.4 - Additional changes related to the check for Admin. privilegs. Version 4.2010.3 - Check for Administrator privilegs during the close of the settings window changed. Version 4.2010.2 - Date and Time will be calculatetd only one time for all dimensions Version 4.2010.1 - Fix of problem with possitivem reporting (Car body mode). Version 4.4.103 - Password for ftp-Upload will be with character "*" showed. Version 4.4.102 - PC-DMIS Object library 2010 *.tlb will be used - K2216 - Master - Serial number will be supported as tracefield command (alphanumerical, 20 character) Version 4.4.101 - At use of the notation in the DFD+DFX format it is possible in the DFX file writing the characteristics in column. If an output file is already available, become the next measuring in this one near line written. Version 4.4.1 - All program settings are now stored in the file PCDQDAS.ini. This file is placed in the installation folder of the converter. The ini file will be created after the first start of the application. - Installtion informations are stored in the registry key: HKEY_LOCAL_MACHINE\SOFTWARE\HexMetGermany\PCDQDAS Version 4.3.210 - Bug Fix: Error while checking the value for K0015. Only values 0, 10 or 20 are allowed by the Q-DAS specification. The field will be used as a Tracefield command in the part program. Version 4.3.209 - Added the possibility to save a local copy of the Q-DAS ASCII file after the file is copied to the target folder. The local copy will be saved in the folder {Install directory}\PartData\Save Version 4.3.208 - Added the possibility to manually upload a file to ftp server. - Change in Ford naming rule to support also the new Global Measuring Point Label which is using up to 12 characters. The old 10charcter label is still supporte. The converter recognize the correct rule by the length of the label. Version 4.3.207 - Added support for K-Field K1005, K1102, K1206, K1302 and K1343 on part level. Values can be send by a tracefield command in part program. - Added support for K-Field K0014, K0015, K0016 und K0017 on characteristic level. Values can be send by a tracefield command in part program. K0015 can include only integer value 0, 10 or 20. Version 4.3.206 Fixed a problem with the positive reporting variable during DXF generation. Version 4.3.205 - POSITIVREPORTING will be used only for X,Y,Z - Removed PC-DMIS Version check Version 4.3.204 - Bug Fix: Use of Tracefield FileName as file name for Q-DAS ASCII file. Version 4.3.203 - POSITIVEREPORTING in Y will be supported. The Nominal, Tolerances and the Measured Values will be mirrored. Version 4.3.202 - Added a "\" to the ftp_cmd and the ftplog.txt file Version 4.3.201 - \PartData\Default.cfg file will be automatically installed - Uses Objekt Library of PC-DMIS 4.3 - ftp-Upload will be done now without an external script. - Change of language files to adjust to the new functionallity Version 4.2.212 - Feature with the last letter X, Y or Z was not used. Version 4.2.211 - When attaching programs the element name in PC-DMIS with the index of the attached program is extended (e.g. from element name one " Feat1" " CS1: Feat1") This extension is removed now with use Ford name regulation. - When using additional axis with element names with the ending P, F, S, E is replaced now the last letter by the oh designator. Thus e.g. U9AA915NCE becomes during the evaluation of the diameter U9AA915NCD or with the length of a slot U9AA915NCL. Before the last designation used thus e.g. U9AA915NCE: X U9AA915NCX Y U9AA915NCY Z U9AA915NCZ D U9AA915NCZ Therfore the data were arranged wrongly in the statistics. Version 4.2.210 - K2022 can be now set in the setup to a fixed number (independent of the Ford naming rule) - Stat commands ON, OFF, TRANSFER support removed from the code - Option buttons for Q-DAS catalog from SQL Database or DFD file removed - Possibility for ftp Upload using a script - User manual adjustments Version 4.2.209 - K2022 changed to value 2 if Ford naming rule is active Version 4.2.208 - All charactersitics with Axis letter M are using now the dimension ID if Ford rule for K2001 and K2002 is enabled. Version 4.2.207 - Problem within Ford name regulation solved (points with V ending were not correctly spent). The name of the previous characteristic was used. - K2434 was additionally workpiece-referred spent. Now this K-field is only characteristic-referred spent. Version 4.2.206 - K2130 and K2131 (plausibility borders down and above) added. In the Setup for both fields a factor were inserted, which multiplies the value for the respective plausibility border by the tolerance down and/or above results in. - Output error with field K2434 corrected (expenditure was missing). - Body mode is now dependent on the command possitives reporting (if this command in the program occurs, the expenditure on 1 is automatically used). Version 4.2.205 - K2434 is now defined for each single characteristic Version 4.2.204 - Fixed error with tracefield K8501 Version 4.2.203 - Fixed error during getting the axis letter in Online mode Version 4.2.202 Adjustments for Ford: K1007, K1210, K1303 added as Tracefield support. K2203 und K2434 added as Tracefield support for all features (/0). Added special Ford naming rule for key fields K2001 and K2002 . These rules can be activatet in the advanced settings area. Key K2001 will use the Ford 10 character feature label. The characters P, F, S und E on the last position will be replaced with the axis letter of PC-DMIS dimension command. Key K2002 will use the same value as K2001 with the extension " / XCOOR", " / YCOOR" oder " / ZCOOR". Checkbox "Support for Stat commands" removed from Setup dialog. Version 4.2.102 Fixed error with license check. Version 4.2.101 Added support for K Felder 1082,1085,1086 and 1087 Version 4.2.100 First Release for BMW Dingolfing +-------------------------------------------------------------------------------+