Index of /PC-DMIS/PC-DMIS_Q-DAS_Converter/PC-DMIS_Q-DAS_Converter_Version_4/Docs
Name Last modified Size Description
Parent Directory -
User Manual.pdf 2017-03-09 11:16 1.4M
ReadMe.txt 2017-03-09 11:16 15K
PCDQDAS Konverter Installation.pdf 2017-03-09 11:16 59K
LiesMich.txt 2017-03-09 11:16 17K
EN PCDQDAS Konverter Installation.pdf 2017-03-09 11:16 59K
Bedienerhandbuch.pdf 2017-03-09 11:16 1.4M
+-------------------------------------------------------------------------------+
| This file include all information's about Changes in the different Versions. |
| |
| xxxx represent the PC-DMIS supported PC-DMIS Main Version |
| y represent the PC-DMIS supported MR Number of the Main Version |
+-------------------------------------------------------------------------------+
Version 4.xxxx.y49
- Added support for K1003 (Part Short Description) as Tracefield value.
Output is only done if a value is defined in the measuring routine.
- Changed K0010 and K0012 from Type Integer to Long. By this change now 10 digits
can be supported.
Version 4.xxxx.y48
- Added Support for K2015/0 and K2015.
Value 0,1 or 2 will be send by tracefield using name K2015 for one individual
dimension axis. If a dimension is using more then one axis the values will be
separated in one tracefiled with ','. Example: 1,0,2
A default value can be set by a tracefield using name K2015/0. The value will
be used for each axis which is not defined individually.
Version 4.xxxx.y47
- K2009 Value for characteristic type FCF Flatness changed (from 102 to 101)
- Additional rule for K2002 (Characteristic name) added in the advanced settings.
This rule is using only the Feature 1 ID and tthe axis letter. No other feature
or dimension IS's will be used.
- Format check for K0008 changed from Typ Integer to Long.
Version 4.xxxx.y46
- Problem with dual arm machines and Protocol Comments for K2002 fixed
Version 4.xxxx.y45
- Added support for K2093/0. Value will be send by tracefield using name K2093/0.
- Added support for K2095/0. Value will be send by tracefield using name K2095/0.
- Added support for K2096/0. Value will be send by tracefield using name K2096/0.
- Added support for K2097/0. Value will be send by tracefield using name K2097/0.
- Added support for K2311/0. Value will be send by tracefield using name K2311/0.
Version 4.xxxx.y44
- Added tracefield support for K0005/0 (correct syntax is under the responsibility
of the PC-DMIS part program value)
- Added tracefield support for K0062 to K0063
- Added tracefield support for K0054 to K0060
Version 4.xxxx.y43
- Fix for Online reading of K0061 trace value
Version 4.xxxx.y42
- Added support for K0061
Version 4.xxxx.y41
- Bugfix for Monitoring path. The '\' between the selcted folder and the
subfolder for the part was missing.
Version 4.xxxx.y40
- Added support for control type (Tracefield K2007 and K2007/0).
For dimensions with multiple rows the values can be separated with a comma.
0 no Control
1 conditional Control
2 manual
3 automatic Control
Version 4.xxxx.y39
- Problem fix while reading K2001 and K2003 from a tracefield for the first
characteristics in the part program
Version 4.xxxx.y38
- Ford naming rule "V" uses also RT (before only T)
Version 4.xxxx.y37
- With negative Y coordinates and positive reporting the values of the upper and lower
plausibility limits were twisted.
Version 4.xxxx.y36
- K0002 Attribute was showing 0 as the value if a dimension was not marked, but
the related feature was measured.
Version 4.xxxx.y35
- New argument /O which can be used if the converter should bee started at the end
of the part program. The dimensions will be reasd automatically, but the Q-DAS
Output have to be started from the user.
Version 4.xxxx.y34
- Bug fix in Path name for the Audi PBMS Converter
- Audi PBMS Converter Checkbox in Setup
Version 4.xxxx.y33
- Integration of AUDI PMBS Converter, if DFQ file and Using Line Notation is selected.
AUDI PMBS Converter must be installed din the same folder as PC-DMIS - Q-DAS Converter
(subfolder "PC-DMIS Audi PBMS Konverter")
Version 4.xxxx.y32
- Bug fix for getting the tracefieldvalues for K0006 in combination with
Ford naming rules (up to 20 characters)
Version 4.xxxx.y31
- Bug fix for getting the tracefieldvalues for K2003 in Online mode.
Version 4.xxxx.y30
- K2003 is now supported as a tracefield command. The position of the tracefield
must be before the next dimension command. If the dimension has more than one
axis the values can be separated by a comma. Each single value has maximum 20
characters.
Version 4.xxxx.y29
- With selected Ford naming rules the K-Field K0006 can now use up to 20 characters
(before25).
Version 4.xxxx.y28
- Additional fix for K2005.
- Fix for calculation of plausibility limits in combination with positive reporting.
- With selected Ford naming rules the K-Field K0006 can now use up to 25 characters
(this is not Q-DAS ASCII conform)
Version 4.xxxx.y27
- K2005 characteristic class was defaulted since 4.2.1 of the converter to a value
of 1, if no trace field K2005 in the measuring program for the characteristic
has been defined.
As a result, the globally defined value from the data entry screen of the converter
or the trace field K2005/0 but has been overridden. Now, the value for the single
characteristic is used only on 1, if no individual and no global value has been defined.
Known bug:
- With the use of positive reporting in PC DMIS the plausibility limit is incorrectly
calculate at negative Y-axis nominal values.
Also the positive reporting will be only used only for Y axis values.
Basically the command for the positive
reporting in PC-DMIS must be evaluated in more detail by the converter (which axis?;
what values?)
Version 4.xxxx.y26
- Implemeted check for length of K0006 value in data input form. If the value is longer
as 14 charcters, the software will cut the string to 13 charaters and a '#' will be
insert as Prefix.
Version 4.xxxx.y25
- Bug Fix for calculation of plausibility limits
Version 4.xxxx.y24
- With multiplier 0 the output of plausibilty limits can be inhibited (K2130 und K2131)
Known issue:
- If the lower toleranz is higher as the nominal value (positive) the calculation of the
plausibility limits is wrong.
Version 4.xxxx.y23
- Bug Fix for calculation of lower plausibility limit (K230) if the dimension is using
a natural boundary
Fehlerbehebung für Plausibilitätsgrenzenberechnung bei natürlich begrenzten Merkmalen.
Version 4.xxxx.y22
- Bug fix for switch Language.
- If the output format is not writing lines and already exists a file with same name,
a message will be displayed.
Version 4.xxxx.y21
- Bug fix for output of K2900
Version 4.xxxx.y20
- For distance dimensions (pitch points) the converter uses now the dimension ID
instead of the feature 1 ID (if Ford rules are selected).
Version 4.xxxx.y19
- Added Support for K2003 which will include the Feat1 ID (required for Ford CM4D)
Version 4.xxxx.y18
- Fix for Run-time error '380': Invalid property value
Max Value of progress bar was smaller as number of PC-DMIS events. Reason is that
PC-DMIS starting from Version 2011 sends more events as number of commands are
included in the part program
Version 4.xxxx.y17
- Removed the check for Administrator privilegs in the setup dialogs.
Version 4.xxxx.y16
- The line notation has been corrected.
Version 4.xxxx.y15
- Fixed background color in the amin view if the value is less then 0.
Version 4.xxxx.y14
- ftp Upload form always on top
Version 4.xxxx.y13
- Support for K1900 as Tracefield (befor only available in the interface)
- Support for attributive Prüfung (K2004/xx 1) integrated.
PC-DMIS Examplecode for such a characteristic:
ASSIGN/YES_STRING=GETSETTING("LangStr(YES)")
TRACEFIELD/NO_DISPLAY,LIMIT=15 ; K2001 : AMM1
C1 =COMMENT/YESNO,NO,FULL SCREEN=NO,AUTO-CONTINUE=NO,
Please check the charasteristic manually.
Is the part OK?
Part OK: Please press <YES>
Part not OK: Please press <No>
IF/C1.INPUT==YES_STRING
ASSIGN/ATCHECK=1
END_IF/
ELSE/
ASSIGN/ATCHECK=0
END_ELSE/
TRACEFIELD/NO_DISPLAY,LIMIT=1 ; K2004 : ATCHECK
Version 4.xxxx.y12
- Fix in combination with K2009 and Feature Control Frames
Version 4.xxxx.y11
- Support for K1083, K1201 as Tracefield command
- Support for K2009 (will be automatically detected by the dimension type)
Version 4.xxxx.y10
- Flip for axis X and Z removed if K2203 is set to 1 (Karosseriemodus)
Version 4.xxxx.y09
- Changed handling of the form if the answer is NO after the part program was
cancled.
Version 4.xxxx.y08
- If a part program execution was canceled, the Q-DAS converter will automatically
pop up in the foreground.
Version 4.xxxx.y07
- Before the Q-DAS ASCII file will be generated the execution status of the
features in the dimension commands will be checked (SKIPPED Property). If the
feature was skipped or unmarked the attribute will be set to 255 or 256. Also
the features in attached part programs will be checked.
Version 4.xxxx.y06
- Code change for the new Registry structure of PC-DMIS (DecimalPrecissionDefaultValue)
Version 4.2010.5 / 4.2009.5
- Software version linked for PC-DMIS 2009 and 2010 .
Version 4.2010.4
- Additional changes related to the check for Admin. privilegs.
Version 4.2010.3
- Check for Administrator privilegs during the close of the settings window changed.
Version 4.2010.2
- Date and Time will be calculatetd only one time for all dimensions
Version 4.2010.1
- Fix of problem with possitivem reporting (Car body mode).
Version 4.4.103
- Password for ftp-Upload will be with character "*" showed.
Version 4.4.102
- PC-DMIS Object library 2010 *.tlb will be used
- K2216 - Master - Serial number will be supported as tracefield command
(alphanumerical, 20 character)
Version 4.4.101
- At use of the notation in the DFD+DFX format it is possible in the DFX file
writing the characteristics in column.
If an output file is already available, become the next measuring in this one
near line written.
Version 4.4.1
- All program settings are now stored in the file PCDQDAS.ini. This file is placed
in the installation folder of the converter. The ini file will be created after
the first start of the application.
- Installtion informations are stored in the registry key:
HKEY_LOCAL_MACHINE\SOFTWARE\HexMetGermany\PCDQDAS
Version 4.3.210
- Bug Fix: Error while checking the value for K0015. Only values 0, 10 or 20 are
allowed by the Q-DAS specification. The field will be used as a Tracefield
command in the part program.
Version 4.3.209
- Added the possibility to save a local copy of the Q-DAS ASCII file after the
file is copied to the target folder. The local copy will be saved in the folder
{Install directory}\PartData\Save
Version 4.3.208
- Added the possibility to manually upload a file to ftp server.
- Change in Ford naming rule to support also the new Global Measuring Point Label
which is using up to 12 characters. The old 10charcter label is still supporte.
The converter recognize the correct rule by the length of the label.
Version 4.3.207
- Added support for K-Field K1005, K1102, K1206, K1302 and K1343 on part level.
Values can be send by a tracefield command in part program.
- Added support for K-Field K0014, K0015, K0016 und K0017 on characteristic level.
Values can be send by a tracefield command in part program.
K0015 can include only integer value 0, 10 or 20.
Version 4.3.206
Fixed a problem with the positive reporting variable during DXF generation.
Version 4.3.205
- POSITIVREPORTING will be used only for X,Y,Z
- Removed PC-DMIS Version check
Version 4.3.204
- Bug Fix: Use of Tracefield FileName as file name for Q-DAS ASCII file.
Version 4.3.203
- POSITIVEREPORTING in Y will be supported. The Nominal, Tolerances and the
Measured Values will be mirrored.
Version 4.3.202
- Added a "\" to the ftp_cmd and the ftplog.txt file
Version 4.3.201
- \PartData\Default.cfg file will be automatically installed
- Uses Objekt Library of PC-DMIS 4.3
- ftp-Upload will be done now without an external script.
- Change of language files to adjust to the new functionallity
Version 4.2.212
- Feature with the last letter X, Y or Z was not used.
Version 4.2.211
- When attaching programs the element name in PC-DMIS with the index of the attached
program is extended (e.g. from element name one " Feat1" " CS1: Feat1")
This extension is removed now with use Ford name regulation.
- When using additional axis with element names with the ending P, F, S, E is replaced
now the last letter by the oh designator. Thus e.g. U9AA915NCE becomes during the
evaluation of the diameter U9AA915NCD or with the length of a slot U9AA915NCL.
Before the last designation used thus e.g.
U9AA915NCE:
X U9AA915NCX
Y U9AA915NCY
Z U9AA915NCZ
D U9AA915NCZ
Therfore the data were arranged wrongly in the statistics.
Version 4.2.210
- K2022 can be now set in the setup to a fixed number (independent of the Ford
naming rule)
- Stat commands ON, OFF, TRANSFER support removed from the code
- Option buttons for Q-DAS catalog from SQL Database or DFD file removed
- Possibility for ftp Upload using a script
- User manual adjustments
Version 4.2.209
- K2022 changed to value 2 if Ford naming rule is active
Version 4.2.208
- All charactersitics with Axis letter M are using now the dimension ID if Ford
rule for K2001 and K2002 is enabled.
Version 4.2.207
- Problem within Ford name regulation solved (points with V ending were not correctly
spent). The name of the previous characteristic was used.
- K2434 was additionally workpiece-referred spent. Now this K-field is only
characteristic-referred spent.
Version 4.2.206
- K2130 and K2131 (plausibility borders down and above) added. In the Setup for both
fields a factor were inserted, which multiplies the value for the respective
plausibility border by the tolerance down and/or above results in.
- Output error with field K2434 corrected (expenditure was missing).
- Body mode is now dependent on the command possitives reporting (if this command
in the program occurs, the expenditure on 1 is automatically used).
Version 4.2.205
- K2434 is now defined for each single characteristic
Version 4.2.204
- Fixed error with tracefield K8501
Version 4.2.203
- Fixed error during getting the axis letter in Online mode
Version 4.2.202
Adjustments for Ford:
K1007, K1210, K1303 added as Tracefield support.
K2203 und K2434 added as Tracefield support for all features (/0).
Added special Ford naming rule for key fields K2001 and K2002 . These rules can be
activatet in the advanced settings area.
Key K2001 will use the Ford 10 character feature label. The characters P, F, S und E
on the last position will be replaced with the axis letter of PC-DMIS dimension command.
Key K2002 will use the same value as K2001 with the extension " / XCOOR", " / YCOOR"
oder " / ZCOOR".
Checkbox "Support for Stat commands" removed from Setup dialog.
Version 4.2.102
Fixed error with license check.
Version 4.2.101
Added support for K Felder 1082,1085,1086 and 1087
Version 4.2.100
First Release for BMW Dingolfing
+-------------------------------------------------------------------------------+