[PARENTDIR] Parent Directory - [   ] 2024-03-26_DE_Preset & Measure Suite.pdf 2024-03-26 09:00 1.1M [   ] 2024-03-26_EN_Preset & Measure Suite.pdf 2024-03-26 09:00 1.3M [   ] Bedienerhandbuch.pdf 2023-11-01 15:28 13M [   ] DE PCD PresetMeasure Installation.pdf 2023-06-21 10:31 207K [   ] DE PCD PresetMeasure Updateanleitung.pdf 2021-11-09 17:29 238K [   ] DE Webinar -VISI_PresetMeasure.zip 2023-03-23 15:53 151M [   ] EN PCD PresetMeasure Installation.pdf 2023-06-21 10:31 219K [   ] EN PCD PresetMeasure Update manual.pdf 2021-11-09 17:29 263K [TXT] ReadMe.txt 2024-01-26 13:59 25K [   ] User Manual.pdf 2023-11-01 15:28 12M
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
+                      PC-DMIS Preset & Measure                            +
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++

Version 3.20XX.X.21 Date SP26.01.2024
- Bug by creating of license request file (DB 324).
- New option for output of preset point.

Version 3.20XX.X.21 Date SP20.12.2023
- Bug by output of QM ASCII file, the nominal value is always zu tip mid point (DB 321).

Version 3.20XX.X.21 Date SP10.10.2023
- New output parameter (output type for Z OFFSET) for Postprocessor (DB 310).

Version 3.20XX.X.21 Date SP22.06.2023
- Others (DB 303, 304).

Version 3.20XX.X.21 Date 16.05.2023
- By switch of measurement type, measurement button switch to correct mode (DB 269, 280).
- Position on the palet can be used for preset file extension (DB 270).
- New post processor option, count of digits as by macro output (DB 271).
- New function, load language (DB 277).
- Bug, by export/import of results list (DB 281).
- New tool "Products Reporting Tool" will be installed with the P&M installations routine (DB 283).
- Bug by run of pallet measurement (DB 285).
- New function, for QM macro with best fit structure can be use by measurement the preset position (DB 286, 287).
- New function, macro type user defined (DB 288).
- New function, macro type can be save and load (DB 289).
- New option for creating of QM macro. The Z preset value can be output to Z zero point or only deviation, by best fit macro type (DB 290, 298).
- New layout by macro settings (DB 291).
- New option, the macto type best fit can be combined with the preset alignment (DB 295).
- New option "Used z points counter" for preset area by  QM with preset macro. The option selected the template with 1,2 or 3 points for Z (DB 296).
- Others (DB 272, 276, 278, 279, 282, 284, 292, 294, 300).

Version 3.20XX.X.20 Date SP24.10.2022
- New Engine.dll and Engine_PCDLRN.pdb files.

Version 3.20XX.X.20 Date SP02.08.2022
- Bug, temp comp command by system macros was not anabled.

Version 3.20XX.X.20 Date 08.07.2022
- Possibility to select and start of QM measurements by more than one row(DB 86).
- New function, for creating of a user TempComp list(DB 223).
- Support of  *.json setting files(DB 227).
- New type of post processor for QM measurement(DB 229).
- New setting for QM default post processor(DM 230, 231).
- New input box by license request(DB 233).
- Bug, by "Preset values from file"(DB 235).
- Bug, if the mouse is moving over start buttons was the last settings by calibration wrong showed(DB 238).
- Angle output will be always between 0-360 Deg.(DB 241).
- If the "Load language from PC-DMIS" option is available in the settings area, the language is used immediately (DB 242).
- By all of QM macro types will be written values X,Y,Z,A,B,C(DB 243).
- Bug, if the mouse is moving over the Postprocessor(DB 246).
- Support of UTF 8 Format (*.xml) file type for list of measurement values(DB 247).
- Bug, by the function "Show Picture" if the macro is points using(DB 248).
- Import and export of settings, improved(DB 251).
- Bug, if the mouse is moving over post processor area but no post processor was defined(DB 252).
- Bug, if no support points are defined on measuremend of a circle(DB 253).
- New function, the Information about the X+,Y+,X-,Y- and axis switch, will be with the measurement data written.
  and by using of the Date used for calculation of Preset data for the *.adf file(DB 258, 263).
- New function, the Information about the fixture place on the pallet where was part measured, will be with the measurement data written.(DB 259).
- New extension option "fixture place" for name of output file by post processing(DB 260).
- New extension option "fixture place" for name of output file by QM post processing(DB 261).
- New function by QM measurement, variables "Firstrun" und "Lastrun" are supported(DB 262).
- New function for quick selection of measurement rows on one pallet(DB 264).
- New function, the alignment and fixture place are displayed by mouse moving over the measurement results(DB 265, 266).
- New function, fixture place can be defined for output by Preset and QM post processing(DB 267, 268).
- New setting, for defining of Z point location of CMM(DB 273).
- New function, for PC-DMIS restart(DB 274).
- New function, check of started applications on application start (DB 275).
- Others(DB 218, 219, 221, 222, 224, 225, 226, 228, 232, 236, 239, 249, 256, 257).

Version 3.20XX.X.19 Date SP25.02.2022
- Bug, lists and other data are replaced (DB 244).
- Message temperature kompensation command is missing (DB 245).

Version 3.20XX.X.19 Date SP10.02.2022
- Bug, by writing of QM macro (DB 234).

Version 3.20XX.X.19 Date 03.12.2021
- New function for settings, by set of column count value row counter will be calculated (DB 94).
- New function for setting of additional parameters by QM file (DB181).
- Modificated lists are saved in the installation folder (DB 194).
- Modificated post processors are saved in the installation folder (DB 195).
- The function for copy of files was modificated, files will be copied if the cmm interface is changed. No files will be copied on offline mode run (DB 196).
- Function bug, on run of macro from folder (DB 198).
- Function bug by post processor, if a post processor is used by pallet run, the offset values where only from the last measurement (DB 199).
- Bud, info post processor failed by run of a work session (DB 201).
- Bug, by enter of number of pre-decimal places, by post processor (DB 203).
- New post processor setting, for definition of decimal separator "." or "," (DB 206).
- New setting, for "on" or "off" of form error detection on using of pallet run (DB 211).
- New post processor setting, for definition of output file format "ANSI" or "UTF8" (DB 213).
- New licence option "Time limited" (DB 216).
- New function, for opening of "User Manual" (DB 217).
- Others (DB 192, 193, 202, 204, 205, 207,214 , 215, 220).

Version 3.20XX.X.17 Date 06.08.2021
- Check of Calibration and Chuck Data midificated.
- Check of interface modificated.

Version 3.20XX.X.16 Date 29.06.2021
- Mode area is not displayed for self-created lists (DB 172).
- New function for postprocessor, the length of the output string can be defined (DB 173).
- Image of the macro and the alignment is superimposed during the measurement (DB 174).
- New option for postprocessor, support of LF and TAB (DB 175).
- New options for postprocessor, possibility to get values from: macro, manually input, input file (DB 176, 178).
- New function for monitoring of probs and chucks (DB 177).
- On delete of postprocessor, the user has to accept it (DB 179).
- Postprocessor modified by measuremant with a pallet (DB 187).
- Error after a pallet measurement and activation of the "Display / Output" tab (DB 186).
- Function measure circle or point modified (DB 189).
- Macros are saved by PC-DMIS version 2016 (DB 191).
- Translation correction (DB 184, 185).
- Others (DB 180, 188, 190)

Version 3.20XX.X.15 Date 12.04.2021
- Menu function "CMM move to the clearpoint" in doesn't enabled by manual devices (DB 159).
- On QM macros, the CMM is moving over the position of first point, before the point teaching (DB 56).
- All question on update of Preset & Measure are by one input form (DB 105).
- Bug, the alignment was not available by menu set settings... (DB 111).
- Settings area for lists is not available by customised lists (DB 112, 113).
- Default setting for *.PDF file is macro name with extension .PDF (DB 117).
- P&M test with PC-DMIS 2020 R2(DB 126).
- New settings option, for printing of normal or 3D *.PDF printing (DB 142).
- Bug, by switch of units, the place settings are calculated to the new unit (DB 143).
- The build of executable, will be show by "Info about..." area (DB 144).
- Bug, by function list, if a customer macro is used and the option "Create ASCII results file" is active (DB 157).
- New devices with RDS interfaces are supported (DB 160).
- By post processor all ASCII characters can be used (DB 162).
- Preset & Measure chects access rights before a file will by written or checks existing of address of output file by post processor (DB 166).
- If the option "After part program execution switch to <Display/Output> tab" is in using, the macro will be unchecked on end of the measurement (DB 167).
- Default grid counter col=6, row=4 (DB 169).
- Others (DB 115, 146, 161, 164, 165, 168, 169, 170, 171).

Version 3.20XX.X.14 Date 04.01.2021
- Support option for manual devices (DB 150, 151, 152, 153).
- The message about safety point doesn't set, comes not by manually devices (DB149).
- The show of settings for AUTO Cell switch to not enabled for manually devices (DB153).

Version 3.20XX.X.13 Date 27.11.2020
- The settings folder "Preset & Measure" has migrated from "C:\ProgramData\" to the area "C:\Users\Public\Documents\Hexagon\" (DB45).
- Settings lost by using of macro "Rectangle_TeachpointsFromFile" or "Cirlcle_TeachponitsFromFile" and using the option "Parameter from file" (DB88).
- Bug, if PC-DMIS shows a comment, is was not possible to break the measuremant (DB89).
- On import and export of Preset & Measure settings, is no more possible to use other areas until the ex/import function is finished (DB90).
- On user mode (password saved), is no more possible to select area "Lists" (DB91).
- Bug, on creation of post processor, if not all settings are seated (DB92).
- Bug, if permission failed for folder where post processor has to be written (DB93).
- Bug, Part and Electrode index goes lost on changing of a list (DB95).
- Bug, single/pallet run  buttons (MAN,MAN/CNC,CNC) are not visible after using of calibration routine for probs by Electrode or Part list (DB96).
- Bug, single/pallet run  buttons (MAN,MAN/CNC,CNC) are not visible after using of calibration routine for chucks by Electrode or Part list (DB97).
- Language bug and changing of translation (DB 103, 104, 120, 129).
- Software crash by list "Macros from folder" if the mouse is moving over the postprocessor area (DB109).
- Bug, after chenging of unit setting, the measurement is running with the old setting (DB110).
- Bug, Settings of axis direction failed if a work session or chuck was recalled (DB114).
- Bug, by oferwrithing of settings of a function cell, inside of post processor (DB125).
- New macros linked to the user interface (DB128).
- Bug, by uninstalling of Preset & Measure about area "Programs und Features" (DB133).
- Bug, on changing of the language (DB135).
- Bug, if the mesuremant was running with a manual mode, the line IF/MODE=="MAN/CNC" inside of macro will chnged to IF/MODE=="MAN/CNC", goto= (DB136).
- New function, by using of PC-DMIS 2020R2 and newer, uses the Preset & Measure the 3D PDF (DB137).
- Bug, on using of Q-DAS Converter. The Conferter path was not found (DB138).
- Neu Function, it is possible to use preset measuremant with a QM file without any points (DB140).
- Bug, Values of HP point where lost, if the list is a customer list (DB141).

Version 3.20xx.x.12 SP10.09.2020 Date 10.09.2020
- Bug by start of run inside of AUTOCell if the Values have to use form Preset & Measure (Values where allways o).

Version 3.20XX.X.12 Date 13.07.2020
- XML Format is a new format for settings file.
- Index error by select macro Preset_Circle_TeachpointsFromFile... .

Version 3.20XX.X.11 Date 21.11.2019
- New Variable, APPEinstellungen.DelayTimeOnStartMeasuremantInsideOfAUTOCELL inside of [Delay Time] area.

Version 3.20XX.X.10 Date 18.09.2019
- If a macro does not have a temperature compensation command and the Preset & Measure option is enabled,
  then function macros will test whether the installed macro can be copied.
- it is possible to cancel a measurement if user have first pressed Hold button.
- New function, the start of the measurement is only possible if all settings are set correctly.
- Tooltip text for start button was modified.
- Inside of QM wirch preset run, is possible to set project data.
- New function, the old settings will be archivate, if the save settings button is pressed.
- License request crearor modified.

Version 3.20XX.X.9 Date 21.08.2019
- New function, HP offset values for parts and electrodes will be separated and stored.
- Bug in language files fixed.
- New option, if P&M is used on a manual CMM, don't come the message about the safety point.

Version 3.20XX.X.8 Date 19.08.2019
- New function for the post processor, a counter.
- Macros inside of DCC Mode modified.
- New types of post processors "AGI" and "SODICK".

Version 3.20XX.X.7 Date 22.07.2019
- Mapped path starting with "\\" is sent to variable into the part program with "\\\".
- By using of +GF+ Job Manager, the offset values can be writen into the CMM_AUXDATA.TXT.
  The offset values are writen
  into the QM file --> if the measuring program is a QM file.
  into the "path robot\RunningFiles\RunningMacro.adf" --> if the measuring program is a *.prg file
- Distance from the edge in X and Y direction, can be defined (Roeders "Preset parameter").
- If TempData.dat exists inside of program folder, it will be deleted on start of any macro. 
- Output of min, max and mean T value in the protocol.
- If the Supervisor or Preset & Measuer will be closed, the Application closes PC-DMIS and Supervisor, by work with the PC-DMIS Preset & Measure Supervisor.
- Corrections by Language files.
- Plausibility test of imported results file.
- Settings handling modified (QM area).
- Corrects error when tab is clicked and macro for e.g. a point has been selected.
- Bug, if list "Macros from folder" is activated and new settings was saved.
- New possibility, if the Preset and QM run is used together, is now possible to use different probes for Preset and for QM area.

Version 3.20XX.X.6 Date 22.02.2019
- Server overloaded when PC-DMIS 2018R2 is used.
- Information about Offset file, was not created inside of end file,
  if manually run was started from the AUTOCELL.

Version 3.20XX.X.5 Date 15.02.2019
- System.Globalization.CultureInfo = NewCulture.SetCulture(FolderAlleUserEinstellungen, "en-US") on start of "MacroSettings" menu. 
- "Z" Value detection on default macros is modified.
- Bug, on saving of new user name

Version 3.20XX.X.4 Date 19.11.2018
- Supported of Roeders Job Manager.
- New Function, the User can set preset parameters, inside of the panel window directly. 
- Error on switch to Portuguese language.
- Export and import of all settings, modified.
- New function for detecting of TempComp command inside of macro.
- New post processor option, for output of Z preset value. With or without used sparkgap.
- Setting switch MM to INCH modified.

Version 3.20XX.X.3 Date 09.07.2018
- Error message, if language changed and any list was updated.
- In the list Alignment, machine is moving to clarence point in Z direction
  independently form CMM Zero Position 

Version 3.20XX.X.2 Date 21.06.2018
- New layout

Version 3.20XX.X.1 Date 05.04.2018
- Possibility to use Add on DLL's
- New function, 6 access point for Add ons.

Version 2.20XX.X.57 Date 19.02.2018
- Culture "en-US" will be set for the Application.

Version 2.20XX.X.56 Date 13.02.2018
- Error on start grid area, by RMC outside of selected Macro.

Version 2.20XX.X.55 Date 02.01.2018
- Settings management has been modified (folder <LanguageFiles> can't be saved).
- Best Fit method has been modified (VECTOR_LST_SQR is now used).
- TempComp Origin value will be set by to 0+0,0+0,0+0 by Start if the part name inside of macro is not "Ausrichtug_Halter_Variabel" and "Keep Origin Values".
- By  part name = "Ausrichtug_Halter_Variabel" or "Keep Origin Values", the Origins don't will be manipulated.

Version 2.20XX.X.54 Date 18.04.2018
- New function, possibility to set count of offset Results lines.
- New function, possibility to set the number of displayed result rows.
- Not existing variables are automatically written into the macro (standard macros).

Version 2.20XX.X.53 Date 08.01.2018
- Check for probe calibration and chuck, modified.
- New Function, Output of ABC Angle options.
- New Function, QM and Preset macro inside of one run.
- New Function <Assign IP preset file to a QM file>.
- New Function <Remove from QM file IP preset file reference>.
- The set settings area was modified.

Version 2.20XX.X.52 Date 21.11.2017
- Error by QM macro writing on the line 3336.

Version 2.20XX.X.51 Date 17.11.2017
- Deleting of selected measurement data was modified.
- The last list is loaded if the connection to PC-DMIS Preset & Measure Supervisor has been deactivated.
- New function, the angles which are read after the measurements, can be defined.

Version 2.20XX.X.50 Date 14.10.2017
- The Format (ANSI) of Temperature coefficient file is changed to Unicode format.
- New input file type can be used for the run defined, extensions can be defined inside of file <C:\ProgramData\PCDMIS_Preset & Measure\AdditionalFiles\File(s)Extention(s).txt>.

Version 2.20XX.X.49 Date 05.09.2017
- Temperature coefficient choice by QM Macro settings.

Version 2.20XX.X.48 Date 05.09.2017
- Macros were modified for the work with a temperature compensation.
- License area for temporary license were modified.

Version 2.20XX.X.47 Date 22.08.2017
- LMS License String can be used for the temporary license database.
- Error by input of Password.
- New function, possibility to set an offset value for the preset angle A, B or C.
- New funstion for QM macro. The file name and path for PDF file and macro, comes from the name of input ini file.
  Is an option by settings editor.

Version 2.20XX.X.46 Date 28.06.2017
- New function, possibility to set offset values for the preset point. The coordinates of preset point will be with offsets calculated.

Version 2.20XX.X.45 Date 23.06.2017
- QM macro, new function for start of existing QM macros with AUXDATAFILE(New format, created for Preset & Measure).
- LMS license string is checked for the license.
- Error on Supervisor start, if the Chuck ID was a number.
- The report template could be set, directly on the main form.

Version 2.20XX.X.44 Date 15.05.2017
- Release of the objects has been processed when a manual measurement has been started via the PC-DMIS Supervisor.
- W10 compatible.
- Bug by visibility of PC-DMIS when in macro is Userform using.
- New Timer for refreshing of list, of macros from folder.
- By QM macro writing, a new command (goto safety position) will be written, before Probe will be changed.
- After save as a list, the new list will be selected.
- New menu item "Delete postprocessor".
- Angle calculation Correction from PC-DMIS version 2017.
- New report template "CADONLY_EDM.rtp" for EDM is available.
- QM macro, new structure and function for variable Preset run.

Version 2.20XX.X.43 Date 22.02.2017
- New function, on saving of work sessions are all settings saved.
- New option, PC-DMIS Preset & Measure can be start with the language that was seted by PC-DMIS.
- New option, by QM can be defined 2D point output.
- New option, Reporttemplate for PC-DMIS Preset & Measure, can be defined.
- New option, temperature compensation can be used.


Version 2.20XX.X.42 Date 23.01.2017
- New function, if the function Feature is inside of a loop, P&M write all Loop offsets.
- New Postprocessor function, the Loop Index can be used for the offset data file.
- New function, Dimensions List with actual values.
- New option, possibility to use of temperature compensation.
- New option, values on the part program head area are written, only when the variables are not ="".
- New option, for the report, can be defined a report template.

Version 2.20XX.X.41 Date 22.11.2016
- New postprocessor System3R.
- New function, Features List with actual values.
- Check of aux data file type.

Version 2.20XX.X.40 Date 16.11.2016
- Bug, if the Macro "Preset_Rectangle_TeachpointsFromFile.PRG" or "Preset_Circle_TeachpointsFromFile.PRG" is started, the second command for PROBEID=PROBE and TIPID=TIP, was demages.
  The right side of assignment has to stay always variable.
- New options by post processor: "String at the end of the file", "Output offset values without decimal separator".

Version 2.20XX.X.39 Date 23.09.2016
- By QM macros, is possible to set pre and retract distance, separated for every points. 
- For languages and settings, is P&M the UTF-8  file format using.
  With the new format are every strings of the World supported.
- key feature is created by Macro Type 1 and 3.

Version 2.20XX.X.38 Date 30.08.2016
- New languages are suported (17 languages).

Version 2.20XX.X.37 Date 22.08.2016
- The part programs are closed with QUIT function (Auto Cell).

Version 2.20XX.X.36 Date 19.08.2016
- Image Search for alignment, changed.

Version 2.20XX.X.35 Date 04.08.2016
- Autocell, "end of run" file will be created if the part program is closed.

Version 2.20XX.X.34 Date 28.07.2016
- Feetback after send commando "Go to park position" in auto-cell.
- Bug in Italian.dll.

Version 2.20XX.X.33 Date 19.07.2016
- New function, possibility to flip Angle ABC.
- Bug, window size on startup.
- Version check for list of programs from a folder off.
- Delay time on close Part Program, can be defined.

Version 2.20XX.X.32 Date 08.07.2016
- IPI.
- Changed license query, if a USB Device is used.

Version 2.20XX.X.31 Date 20.01.2016
- Bug, by counter of startplaces, if col>6, or  row>4

Version 2.20XX.X.30 Date 18.01.2016
- New handling with forms in macro.
- PCDMIS will be start after 100 macro runs.
- Migration of functions vrom settings area into the postprocessor:
  old values when postprocessors override
  Use parts name as the file name
- New setting in the postprocessor, Angleoutput +-180° or 360°.

Version 2.20XX.X.29 Date 04.12.2015
- Bug by A and B angle, calculation.

Version 2.20XX.X.28 Date 07.10.2015
- New function, execute preset(circle, rectangle) or QM macro with a input file .

Version 2.20XX.X.27 Date 27.09.2015
- connected to PC-DMIS 2013 MR1.

Version 2.20XX.X.26 Date 21.09.2015
- New function, Set, Save, Load files or settings.

Version 2.20XX.X.25 Date 12.08.2015
- New function, for automatically writing of QM macro with a input file.
- For Supervisor 1.2011.1.9.

Version 2.20XX.X.24 Date 05.08.2015
- Windows 8.1 compatibility.
- On start Check of permissions.

Version 2.20XX.X.22 Date 18.06.2015
- Show picture function, was customized for the new PC-DMIS Version from 2014.

Version 2.20XX.X.21 Date 18.06.2015
- Bug durch Lesen der letzten Messwerte.

Version 2.20XX.X.20 Date 12.06.2015
- The last setted value of input comment will be shown in remote panel in the main form.

Version 2.20XX.X.19 Date 03.06.2015
- Improved accuracy of the angle calculation CAB.

Version 2.20XX.X.18 Date 04.02.2015
- New function, offset values can be read by hand from a macro.
- Clearance plane is not queried when Manual machine is set,
  or the macro is running in MAN mode.
- New output of offset values.
  Output direction as evaluated, X direction for offset calculation is the C-axis.

Version 2.20XX.X.17 Date 19.01.2015
- New function.Part, Electrode name will be used for the Offset filename (only, one line output).
- New function, all macros from folder.
- New function, Output of oversize value "O".
- New function, Spherecheck, and calculation of Chucks (only for manual mode).
- For a quick test of fixture, new function, measure point and circle.
- New calculation method by post processor (In the direction of the C axis(Shift -> Rotate).
- Bug by calculation zoll-->mm.

Version 2.20XX.X.16 Date 15.09.2014
- New Programs list from a folder. 
  Programs from a folder can be executed.
- Error message, if the command "Clearance plane" doesn't exists, in macro, on manual machines. 
- On post processing will be data formatted only if it is a variable. Number in the text is not formatted.

Version 2.20XX.X.15 Date 26.08.2014
- By post processing, test, is Drive existing.
- CAD will be copied, if exists (AUTO CELL)

Version 2.20XX.X.14 Date 14.07.2014
- Extension of licensing (without dongle).

Version 2.20XX.X.13 Date 03.06.2014
- The AUTO Cell Mode can be activated only in PC-DMIS Supervisor.

Version 2.20XX.X.12 Date 02.06.2014
- License code for demo licenses modified for date notation as in the U.S..
- Bug in <Save as> list function.

Version 2.20xx.x.10     Date: 11.04.2014
 - New output typs "ZO", "XYO", "XYZCO", "XYCO", "XYZCABO", "XYZABO"
 - New option. The use can part, electrode name set as Output file name.
 - Fix. Old values after post processing.
On using the option, write P&M values into the old file.

Version 2.20xx.x.09     Date: 28.02.2014
 - Post Processed date will be written in a temp folder,
   and copy into the destination folder,
   if the job is ready
.
 - New function, possibility to communicate with a AUTO cell.

Version 2.20xx.x.08     Date: 07.11.2013
 - Working sessions can be saved and opened.
 - New function, possibility to set a print format for offset values.
 - New pictures for touch points for alignment.
 - New function,On CNC Machines can be set disabled, on  MAN mode.

Version 2.20xx.x.07     Date: 20.08.2013
 - New pictures for X, Z and Z direction.

Version 2.20xx.x.06     Date: 05.08.2013
 - New macro "E_Center_C_VARIABLE.PRG", available.

Version 2.20xx.x.05     Date: 31.07.2013
 - Release