PC-DMIS Operator Interface Version 2024.1.32 Date 23. Apr. 2024 - Fixed an issue where the top line of the list for clamping places in the pallet run disappeared during the measurement. - Fixed an issue where OI always measured the full pallet at position 1 without factoring the offsets. - New support of for the internal PC-DMIS Qdas interface. Version 2024.1.29 Date 16. Feb. 2024 - Versioning has been changed. - PC-DMIS relevant settings has been moved to new category. - Drag & drop support for images and measurement routines. - Saving of all lists has been changed to UTF-8 format. - Performance optimization at application start. - New option for activate/deactivate the tabs. - Multiple run: new option . - Multiple run: new options for removing routines. - Multiple run: new option for suppress PC-DMIS message "Turn probe". - GUI support has been ended. Version 4.2015.1.21 Date 4. Oct. 2023 - Pallet run: fixed an issue when starting the measurement after an abort. - Pallet Run: fixed an issue where OI has reduced the number of pallet places to measure while waiting for an open watch process. - Hexagon Universal Converter added to default list of watch processes. Version 4.2015.1.20 Date 8. Sep. 2023 - Fixed an issue where the last row in the "Set up pallet run" table was not completely filled with variable values (ReadmeID 132). - Fixed incorrect behavior of the "Suggest same variable value for each measurement routine" option. - Pallet run: fixed an issue when calculating the variable values for and (ReadmeID 135). - Time optimize in palette run (ReadmeID 136). Version 4.2015.1.19 Date 10. Jul. 2023 - Fixed an issue where OI crashes when the Tab key is used in the Palette Run Setup dialog (ReadmeID 108). - Fixed an issue when restarting PC-DMIS by OI. - Fixed an issue when defining a pattern for partial encoding (ReadmeID 119). - Time optimization when loading pallet places. Skipped locations are no longer evaluated internally (ReadmeID 107). - Installer: if required, OI can be installed additionally to existing version. - New option for single and pallet run: confirm manually loaded measuring job (ReadmeID 110). - New option for multiple and pallet run: Permitting of the available closing options in case of measurement abort. - New option for pallet run: switch to the original view after aborting the measurement. - New option for pallet run: suppress PC-DMIS message "Turn probe". - New option for pallet run: Save/load list of variables as default. Version 4.2015.1.18 Date 28. Nov. 2022 - PC-DMIS versions lower than 2015.1 are no longer supported. - Start dialog replaced by a splash screen. - Fixed an issue where writing variables to a measurement routine with closed groups was not possible (ReadmeID 83). - Fixed an issue where PC-DMIS was active as a background process in the Task Manager for a longer of time after closing OI (ReadmeID 86). - Fixed an issue where OI crashed after entering a barcode that was not assigned to a measurement routine (ReadmeID 92). - Maximizing dialogs during execution is supported. - New option: Possibility to start PC-DMIS automatically on start of OI. - New option for pallet run configuration: same variable can be sent automatically to all clamping places (ReadmeID 90). - New option for pallet run: possibility to activate/deactivate all clamping places. - New option for pallet run: Numbering of the clamping places in the pallet view.